Avoid to block the tuning procedure on BIST error (not finished
BIST procedure) by adding a 1000us timeout on the polling of
BISTGSR.BDDONE executed to detect the end of BIST.
The normal duration of the BIST test is around 5us.
This patch also cleanup comments.
Signed-off-by: Patrick Delaunay <patrick.delaunay@st.com>
Acked-by: Patrice Chotard <patrice.chotard@st.com>
Display result information for software read DQS gating, the tuning 0
which be used by CubeMX DDR tuning tools.
Signed-off-by: Patrick Delaunay <patrick.delaunay@st.com>
Acked-by: Patrice Chotard <patrice.chotard@st.com>
Add command tuning for DDR interactive mode, used during
board bring-up or with CubeMX DDR tools to execute software
tuning for the DDR configuration:
- software read DQS Gating (replace the built-in one)
- Bit de-skew
- Eye Training or DQS training
Signed-off-by: Patrick Delaunay <patrick.delaunay@st.com>