4411b2aea7
When swi instruction is executed, it is expected to get message "software interrupt" in console and dump registers and reboot, as do_software_interrupt() in arch/arm/lib/interrupts.c. But, actually it causes data abort accessing wrong address in get_bad_stack_swi macro in arch/arm/cpu/v7/start.S. This patch fixes this problem. The same mistake in arch/arm/cpu/{arm1136,arm1176,pxa}/start.S. Signed-off-by: Tetsuyuki Kobayashi <koba@kmckk.co.jp> |
||
---|---|---|
.. | ||