sunxi: axp221: Fix using the wrong register address for ALDO2

This fixes us never programming ALDO2, and programming the ALDO2 voltage
into ALDo1.

Reported-by: Siarhei Siamashka <siarhei.siamashka@gmail.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
This commit is contained in:
Hans de Goede 2015-01-05 16:41:49 +01:00
parent d622ac3927
commit 5ba471944a

View File

@ -32,7 +32,7 @@
#define AXP221_DCDC4_CTRL 0x24
#define AXP221_DCDC5_CTRL 0x25
#define AXP221_ALDO1_CTRL 0x28
#define AXP221_ALDO2_CTRL 0x28
#define AXP221_ALDO2_CTRL 0x29
#define AXP221_ALDO3_CTRL 0x2a
int axp221_set_dcdc1(unsigned int mvolt);