soc/tegra: pmc: Fix child-node lookup

commit 1dc6bd5e39 upstream.

Fix child-node lookup during probe, which ended up searching the whole
device tree depth-first starting at the parent rather than just matching
on its children.

To make things worse, the parent pmc node could end up being prematurely
freed as of_find_node_by_name() drops a reference to its first argument.

Fixes: 3568df3d31 ("soc: tegra: Add thermal reset (thermtrip) support to PMC")
Cc: stable <stable@vger.kernel.org>     # 4.0
Cc: Mikko Perttunen <mperttunen@nvidia.com>
Signed-off-by: Johan Hovold <johan@kernel.org>
Reviewed-by: Mikko Perttunen <mperttunen@nvidia.com>
Signed-off-by: Thierry Reding <treding@nvidia.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Johan Hovold 2017-11-15 10:44:58 +01:00 committed by Greg Kroah-Hartman
parent fd81a7a647
commit cb526c9ab8
1 changed files with 1 additions and 1 deletions

View File

@ -738,7 +738,7 @@ void tegra_pmc_init_tsense_reset(struct tegra_pmc *pmc)
if (!pmc->soc->has_tsense_reset)
return;
np = of_find_node_by_name(pmc->dev->of_node, "i2c-thermtrip");
np = of_get_child_by_name(pmc->dev->of_node, "i2c-thermtrip");
if (!np) {
dev_warn(dev, "i2c-thermtrip node not found, %s.\n", disabled);
return;