arm64: dts: nxp: ls208xa: add more thermal zone support
Ls208xa has several thermal sensors. Add all the sensor id to dts to enable them. To make the dts cleaner, re-organize the nodes to split out the common part so that it can be shared with other SoCs. Signed-off-by: Yuantian Tang <andy.tang@nxp.com>
This commit is contained in:
parent
a8d347c746
commit
6a5ebd0be1
|
@ -12,7 +12,7 @@
|
|||
#include "fsl-ls208xa.dtsi"
|
||||
|
||||
&cpu {
|
||||
cpu0: cpu@0 {
|
||||
cooling_map0: cpu0: cpu@0 {
|
||||
device_type = "cpu";
|
||||
compatible = "arm,cortex-a57";
|
||||
reg = <0x0>;
|
||||
|
@ -32,7 +32,7 @@
|
|||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu2: cpu@100 {
|
||||
cooling_map1: cpu2: cpu@100 {
|
||||
device_type = "cpu";
|
||||
compatible = "arm,cortex-a57";
|
||||
reg = <0x100>;
|
||||
|
@ -52,7 +52,7 @@
|
|||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu4: cpu@200 {
|
||||
cooling_map2: cpu4: cpu@200 {
|
||||
device_type = "cpu";
|
||||
compatible = "arm,cortex-a57";
|
||||
reg = <0x200>;
|
||||
|
@ -72,7 +72,7 @@
|
|||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu6: cpu@300 {
|
||||
cooling_map3: cpu6: cpu@300 {
|
||||
device_type = "cpu";
|
||||
compatible = "arm,cortex-a57";
|
||||
reg = <0x300>;
|
||||
|
|
|
@ -12,7 +12,7 @@
|
|||
#include "fsl-ls208xa.dtsi"
|
||||
|
||||
&cpu {
|
||||
cpu0: cpu@0 {
|
||||
cooling_map0: cpu0: cpu@0 {
|
||||
device_type = "cpu";
|
||||
compatible = "arm,cortex-a72";
|
||||
reg = <0x0>;
|
||||
|
@ -32,7 +32,7 @@
|
|||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu2: cpu@100 {
|
||||
cooling_map1: cpu2: cpu@100 {
|
||||
device_type = "cpu";
|
||||
compatible = "arm,cortex-a72";
|
||||
reg = <0x100>;
|
||||
|
@ -52,7 +52,7 @@
|
|||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu4: cpu@200 {
|
||||
cooling_map2: cpu4: cpu@200 {
|
||||
device_type = "cpu";
|
||||
compatible = "arm,cortex-a72";
|
||||
reg = <0x200>;
|
||||
|
@ -72,7 +72,7 @@
|
|||
#cooling-cells = <2>;
|
||||
};
|
||||
|
||||
cpu6: cpu@300 {
|
||||
cooling_map3: cpu6: cpu@300 {
|
||||
device_type = "cpu";
|
||||
compatible = "arm,cortex-a72";
|
||||
reg = <0x300>;
|
||||
|
|
|
@ -77,42 +77,7 @@
|
|||
mask = <0x2>;
|
||||
};
|
||||
|
||||
thermal-zones {
|
||||
cpu_thermal: cpu-thermal {
|
||||
polling-delay-passive = <1000>;
|
||||
polling-delay = <5000>;
|
||||
|
||||
thermal-sensors = <&tmu 4>;
|
||||
|
||||
trips {
|
||||
cpu_alert: cpu-alert {
|
||||
temperature = <75000>;
|
||||
hysteresis = <2000>;
|
||||
type = "passive";
|
||||
};
|
||||
cpu_crit: cpu-crit {
|
||||
temperature = <85000>;
|
||||
hysteresis = <2000>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&cpu_alert>;
|
||||
cooling-device =
|
||||
<&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu4 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu5 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu6 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
|
||||
<&cpu7 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
#include "fsl-tmu.dtsi"
|
||||
|
||||
timer: timer {
|
||||
compatible = "arm,armv8-timer";
|
||||
|
@ -907,3 +872,36 @@
|
|||
};
|
||||
};
|
||||
};
|
||||
|
||||
#include "fsl-tmu-map1.dtsi"
|
||||
#include "fsl-tmu-map2.dtsi"
|
||||
#include "fsl-tmu-map3.dtsi"
|
||||
&thermal_zones {
|
||||
thermal-zone1 {
|
||||
status = "okay";
|
||||
};
|
||||
|
||||
thermal-zone2{
|
||||
status = "okay";
|
||||
};
|
||||
|
||||
thermal-zone3{
|
||||
status = "okay";
|
||||
};
|
||||
|
||||
thermal-zone4{
|
||||
status = "okay";
|
||||
};
|
||||
|
||||
thermal-zone5{
|
||||
status = "okay";
|
||||
};
|
||||
|
||||
thermal-zone6{
|
||||
status = "okay";
|
||||
};
|
||||
|
||||
thermal-zone7 {
|
||||
status = "okay";
|
||||
};
|
||||
};
|
||||
|
|
|
@ -0,0 +1,99 @@
|
|||
// SPDX-License-Identifier: (GPL-2.0+ OR MIT)
|
||||
/*
|
||||
* Device Tree Include file for Thermal Monitor Unit.
|
||||
*
|
||||
* Copyright 2018 NXP
|
||||
*
|
||||
* Tang Yuantian <andy.tang@nxp.com>
|
||||
*
|
||||
*/
|
||||
|
||||
&thermal_zones {
|
||||
thermal-zone0 {
|
||||
cooling-maps {
|
||||
map1 {
|
||||
trip = <&alert0>;
|
||||
cooling-device =
|
||||
<&cooling_map1 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone1 {
|
||||
cooling-maps {
|
||||
map1 {
|
||||
trip = <&alert1>;
|
||||
cooling-device =
|
||||
<&cooling_map1 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone2 {
|
||||
cooling-maps {
|
||||
map1 {
|
||||
trip = <&alert2>;
|
||||
cooling-device =
|
||||
<&cooling_map1 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone3 {
|
||||
cooling-maps {
|
||||
map1 {
|
||||
trip = <&alert3>;
|
||||
cooling-device =
|
||||
<&cooling_map1 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone4 {
|
||||
cooling-maps {
|
||||
map1 {
|
||||
trip = <&alert4>;
|
||||
cooling-device =
|
||||
<&cooling_map1 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone5 {
|
||||
cooling-maps {
|
||||
map1 {
|
||||
trip = <&alert5>;
|
||||
cooling-device =
|
||||
<&cooling_map1 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone6 {
|
||||
cooling-maps {
|
||||
map1 {
|
||||
trip = <&alert6>;
|
||||
cooling-device =
|
||||
<&cooling_map1 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone7 {
|
||||
cooling-maps {
|
||||
map1 {
|
||||
trip = <&alert7>;
|
||||
cooling-device =
|
||||
<&cooling_map1 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
|
@ -0,0 +1,99 @@
|
|||
// SPDX-License-Identifier: (GPL-2.0+ OR MIT)
|
||||
/*
|
||||
* Device Tree Include file for Thermal Monitor Unit.
|
||||
*
|
||||
* Copyright 2018 NXP
|
||||
*
|
||||
* Tang Yuantian <andy.tang@nxp.com>
|
||||
*
|
||||
*/
|
||||
|
||||
&thermal_zones {
|
||||
thermal-zone0 {
|
||||
cooling-maps {
|
||||
map2 {
|
||||
trip = <&alert0>;
|
||||
cooling-device =
|
||||
<&cooling_map2 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone1 {
|
||||
cooling-maps {
|
||||
map2 {
|
||||
trip = <&alert1>;
|
||||
cooling-device =
|
||||
<&cooling_map2 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone2 {
|
||||
cooling-maps {
|
||||
map2 {
|
||||
trip = <&alert2>;
|
||||
cooling-device =
|
||||
<&cooling_map2 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone3 {
|
||||
cooling-maps {
|
||||
map2 {
|
||||
trip = <&alert3>;
|
||||
cooling-device =
|
||||
<&cooling_map2 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone4 {
|
||||
cooling-maps {
|
||||
map2 {
|
||||
trip = <&alert4>;
|
||||
cooling-device =
|
||||
<&cooling_map2 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone5 {
|
||||
cooling-maps {
|
||||
map2 {
|
||||
trip = <&alert5>;
|
||||
cooling-device =
|
||||
<&cooling_map2 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone6 {
|
||||
cooling-maps {
|
||||
map2 {
|
||||
trip = <&alert6>;
|
||||
cooling-device =
|
||||
<&cooling_map2 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone7 {
|
||||
cooling-maps {
|
||||
map2 {
|
||||
trip = <&alert7>;
|
||||
cooling-device =
|
||||
<&cooling_map2 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
|
@ -0,0 +1,99 @@
|
|||
// SPDX-License-Identifier: (GPL-2.0+ OR MIT)
|
||||
/*
|
||||
* Device Tree Include file for Thermal Monitor Unit.
|
||||
*
|
||||
* Copyright 2018 NXP
|
||||
*
|
||||
* Tang Yuantian <andy.tang@nxp.com>
|
||||
*
|
||||
*/
|
||||
|
||||
&thermal_zones {
|
||||
thermal-zone0 {
|
||||
cooling-maps {
|
||||
map3 {
|
||||
trip = <&alert0>;
|
||||
cooling-device =
|
||||
<&cooling_map3 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone1 {
|
||||
cooling-maps {
|
||||
map3 {
|
||||
trip = <&alert1>;
|
||||
cooling-device =
|
||||
<&cooling_map3 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone2 {
|
||||
cooling-maps {
|
||||
map3 {
|
||||
trip = <&alert2>;
|
||||
cooling-device =
|
||||
<&cooling_map3 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone3 {
|
||||
cooling-maps {
|
||||
map3 {
|
||||
trip = <&alert3>;
|
||||
cooling-device =
|
||||
<&cooling_map3 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone4 {
|
||||
cooling-maps {
|
||||
map3 {
|
||||
trip = <&alert4>;
|
||||
cooling-device =
|
||||
<&cooling_map3 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone5 {
|
||||
cooling-maps {
|
||||
map3 {
|
||||
trip = <&alert5>;
|
||||
cooling-device =
|
||||
<&cooling_map3 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone6 {
|
||||
cooling-maps {
|
||||
map3 {
|
||||
trip = <&alert6>;
|
||||
cooling-device =
|
||||
<&cooling_map3 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone7 {
|
||||
cooling-maps {
|
||||
map3 {
|
||||
trip = <&alert7>;
|
||||
cooling-device =
|
||||
<&cooling_map3 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
|
@ -0,0 +1,251 @@
|
|||
// SPDX-License-Identifier: (GPL-2.0+ OR MIT)
|
||||
/*
|
||||
* Device Tree Include file for Thermal Monitor Unit.
|
||||
*
|
||||
* Copyright 2018 NXP
|
||||
*
|
||||
* Tang Yuantian <andy.tang@nxp.com>
|
||||
*
|
||||
*/
|
||||
|
||||
thermal_zones: thermal-zones {
|
||||
thermal_zone0: thermal-zone0 {
|
||||
polling-delay-passive = <1000>;
|
||||
polling-delay = <5000>;
|
||||
thermal-sensors = <&tmu 0>;
|
||||
status = "disabled";
|
||||
|
||||
trips {
|
||||
alert0: alert0 {
|
||||
temperature = <75000>;
|
||||
hysteresis = <2000>;
|
||||
type = "passive";
|
||||
};
|
||||
|
||||
crit0: crit0 {
|
||||
temperature = <85000>;
|
||||
hysteresis = <2000>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&alert0>;
|
||||
cooling-device =
|
||||
<&cooling_map0 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone1 {
|
||||
polling-delay-passive = <1000>;
|
||||
polling-delay = <5000>;
|
||||
thermal-sensors = <&tmu 1>;
|
||||
status = "disabled";
|
||||
|
||||
trips {
|
||||
alert1: alert1 {
|
||||
temperature = <75000>;
|
||||
hysteresis = <2000>;
|
||||
type = "passive";
|
||||
};
|
||||
|
||||
crit1: crit1 {
|
||||
temperature = <85000>;
|
||||
hysteresis = <2000>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&alert1>;
|
||||
cooling-device =
|
||||
<&cooling_map0 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone2 {
|
||||
polling-delay-passive = <1000>;
|
||||
polling-delay = <5000>;
|
||||
thermal-sensors = <&tmu 2>;
|
||||
status = "disabled";
|
||||
|
||||
trips {
|
||||
alert2: alert2 {
|
||||
temperature = <75000>;
|
||||
hysteresis = <2000>;
|
||||
type = "passive";
|
||||
};
|
||||
|
||||
crit2: crit2 {
|
||||
temperature = <85000>;
|
||||
hysteresis = <2000>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&alert2>;
|
||||
cooling-device =
|
||||
<&cooling_map0 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone3 {
|
||||
polling-delay-passive = <1000>;
|
||||
polling-delay = <5000>;
|
||||
thermal-sensors = <&tmu 3>;
|
||||
status = "disabled";
|
||||
|
||||
trips {
|
||||
alert3: alert3 {
|
||||
temperature = <75000>;
|
||||
hysteresis = <2000>;
|
||||
type = "passive";
|
||||
};
|
||||
|
||||
crit3: crit3 {
|
||||
temperature = <85000>;
|
||||
hysteresis = <2000>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&alert3>;
|
||||
cooling-device =
|
||||
<&cooling_map0 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone4 {
|
||||
polling-delay-passive = <1000>;
|
||||
polling-delay = <5000>;
|
||||
thermal-sensors = <&tmu 4>;
|
||||
status = "disabled";
|
||||
|
||||
trips {
|
||||
alert4: alert4 {
|
||||
temperature = <75000>;
|
||||
hysteresis = <2000>;
|
||||
type = "passive";
|
||||
};
|
||||
|
||||
crit4: crit4 {
|
||||
temperature = <85000>;
|
||||
hysteresis = <2000>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&alert4>;
|
||||
cooling-device =
|
||||
<&cooling_map0 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone5 {
|
||||
polling-delay-passive = <1000>;
|
||||
polling-delay = <5000>;
|
||||
thermal-sensors = <&tmu 5>;
|
||||
status = "disabled";
|
||||
|
||||
trips {
|
||||
alert5: alert5 {
|
||||
temperature = <75000>;
|
||||
hysteresis = <2000>;
|
||||
type = "passive";
|
||||
};
|
||||
|
||||
crit5: crit5 {
|
||||
temperature = <85000>;
|
||||
hysteresis = <2000>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&alert5>;
|
||||
cooling-device =
|
||||
<&cooling_map0 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone6 {
|
||||
polling-delay-passive = <1000>;
|
||||
polling-delay = <5000>;
|
||||
thermal-sensors = <&tmu 6>;
|
||||
status = "disabled";
|
||||
|
||||
trips {
|
||||
alert6: alert6 {
|
||||
temperature = <75000>;
|
||||
hysteresis = <2000>;
|
||||
type = "passive";
|
||||
};
|
||||
|
||||
crit6: crit6 {
|
||||
temperature = <85000>;
|
||||
hysteresis = <2000>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&alert6>;
|
||||
cooling-device =
|
||||
<&cooling_map0 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zone7 {
|
||||
polling-delay-passive = <1000>;
|
||||
polling-delay = <5000>;
|
||||
thermal-sensors = <&tmu 7>;
|
||||
status = "disabled";
|
||||
|
||||
trips {
|
||||
alert7: alert7 {
|
||||
temperature = <75000>;
|
||||
hysteresis = <2000>;
|
||||
type = "passive";
|
||||
};
|
||||
|
||||
crit7: crit7 {
|
||||
temperature = <85000>;
|
||||
hysteresis = <2000>;
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&alert7>;
|
||||
cooling-device =
|
||||
<&cooling_map0 THERMAL_NO_LIMIT
|
||||
THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
Loading…
Reference in New Issue