Linux Driver for Mylex DAC960/AcceleRAID/eXtremeRAID PCI RAID Controllers
|
|
||||||
|
|
||||||
Version 2.2.11 for Linux 2.2.19
|
|
||||||
Version 2.4.11 for Linux 2.4.12
|
|
||||||
|
|
||||||
PRODUCTION RELEASE
|
|
||||||
|
|
||||||
11 October 2001
|
|
||||||
|
|
||||||
Leonard N. Zubkoff
|
|
||||||
Dandelion Digital
|
|
||||||
lnz@dandelion.com
|
|
||||||
|
|
||||||
Copyright 1998-2001 by Leonard N. Zubkoff <lnz@dandelion.com>
|
|
||||||
|
|
||||||
|
|
||||||
INTRODUCTION
|
|
||||||
|
|
||||||
Mylex, Inc. designs and manufactures a variety of high performance PCI RAID
|
|
||||||
controllers. Mylex Corporation is located at 34551 Ardenwood Blvd., Fremont,
|
|
||||||
California 94555, USA and can be reached at 510.796.6100 or on the World Wide
|
|
||||||
Web at http://www.mylex.com. Mylex Technical Support can be reached by
|
|
||||||
electronic mail at mylexsup@us.ibm.com, by voice at 510.608.2400, or by FAX at
|
|
||||||
510.745.7715. Contact information for offices in Europe and Japan is available
|
|
||||||
on their Web site.
|
|
||||||
|
|
||||||
The latest information on Linux support for DAC960 PCI RAID Controllers, as
|
|
||||||
well as the most recent release of this driver, will always be available from
|
|
||||||
my Linux Home Page at URL "http://www.dandelion.com/Linux/". The Linux DAC960
|
|
||||||
driver supports all current Mylex PCI RAID controllers including the new
|
|
||||||
eXtremeRAID 2000/3000 and AcceleRAID 352/170/160 models which have an entirely
|
|
||||||
new firmware interface from the older eXtremeRAID 1100, AcceleRAID 150/200/250,
|
|
||||||
and DAC960PJ/PG/PU/PD/PL. See below for a complete controller list as well as
|
|
||||||
minimum firmware version requirements. For simplicity, in most places this
|
|
||||||
documentation refers to DAC960 generically rather than explicitly listing all
|
|
||||||
the supported models.
|
|
||||||
|
|
||||||
Driver bug reports should be sent via electronic mail to "lnz@dandelion.com".
|
|
||||||
Please include with the bug report the complete configuration messages reported
|
|
||||||
by the driver at startup, along with any subsequent system messages relevant to
|
|
||||||
the controller's operation, and a detailed description of your system's
|
|
||||||
hardware configuration. Driver bugs are actually quite rare; if you encounter
|
|
||||||
problems with disks being marked offline, for example, please contact Mylex
|
|
||||||
Technical Support as the problem is related to the hardware configuration
|
|
||||||
rather than the Linux driver.
|
|
||||||
|
|
||||||
Please consult the RAID controller documentation for detailed information
|
|
||||||
regarding installation and configuration of the controllers. This document
|
|
||||||
primarily provides information specific to the Linux support.
|
|
||||||
|
|
||||||
|
|
||||||
DRIVER FEATURES
|
|
||||||
|
|
||||||
The DAC960 RAID controllers are supported solely as high performance RAID
|
|
||||||
controllers, not as interfaces to arbitrary SCSI devices. The Linux DAC960
|
|
||||||
driver operates at the block device level, the same level as the SCSI and IDE
|
|
||||||
drivers. Unlike other RAID controllers currently supported on Linux, the
|
|
||||||
DAC960 driver is not dependent on the SCSI subsystem, and hence avoids all the
|
|
||||||
complexity and unnecessary code that would be associated with an implementation
|
|
||||||
as a SCSI driver. The DAC960 driver is designed for as high a performance as
|
|
||||||
possible with no compromises or extra code for compatibility with lower
|
|
||||||
performance devices. The DAC960 driver includes extensive error logging and
|
|
||||||
online configuration management capabilities. Except for initial configuration
|
|
||||||
of the controller and adding new disk drives, most everything can be handled
|
|
||||||
from Linux while the system is operational.
|
|
||||||
|
|
||||||
The DAC960 driver is architected to support up to 8 controllers per system.
|
|
||||||
Each DAC960 parallel SCSI controller can support up to 15 disk drives per
|
|
||||||
channel, for a maximum of 60 drives on a four channel controller; the fibre
|
|
||||||
channel eXtremeRAID 3000 controller supports up to 125 disk drives per loop for
|
|
||||||
a total of 250 drives. The drives installed on a controller are divided into
|
|
||||||
one or more "Drive Groups", and then each Drive Group is subdivided further
|
|
||||||
into 1 to 32 "Logical Drives". Each Logical Drive has a specific RAID Level
|
|
||||||
and caching policy associated with it, and it appears to Linux as a single
|
|
||||||
block device. Logical Drives are further subdivided into up to 7 partitions
|
|
||||||
through the normal Linux and PC disk partitioning schemes. Logical Drives are
|
|
||||||
also known as "System Drives", and Drive Groups are also called "Packs". Both
|
|
||||||
terms are in use in the Mylex documentation; I have chosen to standardize on
|
|
||||||
the more generic "Logical Drive" and "Drive Group".
|
|
||||||
|
|
||||||
DAC960 RAID disk devices are named in the style of the obsolete Device File
|
|
||||||
System (DEVFS). The device corresponding to Logical Drive D on Controller C
|
|
||||||
is referred to as /dev/rd/cCdD, and the partitions are called /dev/rd/cCdDp1
|
|
||||||
through /dev/rd/cCdDp7. For example, partition 3 of Logical Drive 5 on
|
|
||||||
Controller 2 is referred to as /dev/rd/c2d5p3. Note that unlike with SCSI
|
|
||||||
disks the device names will not change in the event of a disk drive failure.
|
|
||||||
The DAC960 driver is assigned major numbers 48 - 55 with one major number per
|
|
||||||
controller. The 8 bits of minor number are divided into 5 bits for the Logical
|
|
||||||
Drive and 3 bits for the partition.
|
|
||||||
|
|
||||||
|
|
||||||
SUPPORTED DAC960/AcceleRAID/eXtremeRAID PCI RAID CONTROLLERS
|
|
||||||
|
|
||||||
The following list comprises the supported DAC960, AcceleRAID, and eXtremeRAID
|
|
||||||
PCI RAID Controllers as of the date of this document. It is recommended that
|
|
||||||
anyone purchasing a Mylex PCI RAID Controller not in the following table
|
|
||||||
contact the author beforehand to verify that it is or will be supported.
|
|
||||||
|
|
||||||
eXtremeRAID 3000
|
|
||||||
1 Wide Ultra-2/LVD SCSI channel
|
|
||||||
2 External Fibre FC-AL channels
|
|
||||||
233MHz StrongARM SA 110 Processor
|
|
||||||
64 Bit 33MHz PCI (backward compatible with 32 Bit PCI slots)
|
|
||||||
32MB/64MB ECC SDRAM Memory
|
|
||||||
|
|
||||||
eXtremeRAID 2000
|
|
||||||
4 Wide Ultra-160 LVD SCSI channels
|
|
||||||
233MHz StrongARM SA 110 Processor
|
|
||||||
64 Bit 33MHz PCI (backward compatible with 32 Bit PCI slots)
|
|
||||||
32MB/64MB ECC SDRAM Memory
|
|
||||||
|
|
||||||
AcceleRAID 352
|
|
||||||
2 Wide Ultra-160 LVD SCSI channels
|
|
||||||
100MHz Intel i960RN RISC Processor
|
|
||||||
64 Bit 33MHz PCI (backward compatible with 32 Bit PCI slots)
|
|
||||||
32MB/64MB ECC SDRAM Memory
|
|
||||||
|
|
||||||
AcceleRAID 170
|
|
||||||
1 Wide Ultra-160 LVD SCSI channel
|
|
||||||
100MHz Intel i960RM RISC Processor
|
|
||||||
16MB/32MB/64MB ECC SDRAM Memory
|
|
||||||
|
|
||||||
AcceleRAID 160 (AcceleRAID 170LP)
|
|
||||||
1 Wide Ultra-160 LVD SCSI channel
|
|
||||||
100MHz Intel i960RS RISC Processor
|
|
||||||
Built in 16M ECC SDRAM Memory
|
|
||||||
PCI Low Profile Form Factor - fit for 2U height
|
|
||||||
|
|
||||||
eXtremeRAID 1100 (DAC1164P)
|
|
||||||
3 Wide Ultra-2/LVD SCSI channels
|
|
||||||
233MHz StrongARM SA 110 Processor
|
|
||||||
64 Bit 33MHz PCI (backward compatible with 32 Bit PCI slots)
|
|
||||||
16MB/32MB/64MB Parity SDRAM Memory with Battery Backup
|
|
||||||
|
|
||||||
AcceleRAID 250 (DAC960PTL1)
|
|
||||||
Uses onboard Symbios SCSI chips on certain motherboards
|
|
||||||
Also includes one onboard Wide Ultra-2/LVD SCSI Channel
|
|
||||||
66MHz Intel i960RD RISC Processor
|
|
||||||
4MB/8MB/16MB/32MB/64MB/128MB ECC EDO Memory
|
|
||||||
|
|
||||||
AcceleRAID 200 (DAC960PTL0)
|
|
||||||
Uses onboard Symbios SCSI chips on certain motherboards
|
|
||||||
Includes no onboard SCSI Channels
|
|
||||||
66MHz Intel i960RD RISC Processor
|
|
||||||
4MB/8MB/16MB/32MB/64MB/128MB ECC EDO Memory
|
|
||||||
|
|
||||||
AcceleRAID 150 (DAC960PRL)
|
|
||||||
Uses onboard Symbios SCSI chips on certain motherboards
|
|
||||||
Also includes one onboard Wide Ultra-2/LVD SCSI Channel
|
|
||||||
33MHz Intel i960RP RISC Processor
|
|
||||||
4MB Parity EDO Memory
|
|
||||||
|
|
||||||
DAC960PJ 1/2/3 Wide Ultra SCSI-3 Channels
|
|
||||||
66MHz Intel i960RD RISC Processor
|
|
||||||
4MB/8MB/16MB/32MB/64MB/128MB ECC EDO Memory
|
|
||||||
|
|
||||||
DAC960PG 1/2/3 Wide Ultra SCSI-3 Channels
|
|
||||||
33MHz Intel i960RP RISC Processor
|
|
||||||
4MB/8MB ECC EDO Memory
|
|
||||||
|
|
||||||
DAC960PU 1/2/3 Wide Ultra SCSI-3 Channels
|
|
||||||
Intel i960CF RISC Processor
|
|
||||||
4MB/8MB EDRAM or 2MB/4MB/8MB/16MB/32MB DRAM Memory
|
|
||||||
|
|
||||||
DAC960PD 1/2/3 Wide Fast SCSI-2 Channels
|
|
||||||
Intel i960CF RISC Processor
|
|
||||||
4MB/8MB EDRAM or 2MB/4MB/8MB/16MB/32MB DRAM Memory
|
|
||||||
|
|
||||||
DAC960PL 1/2/3 Wide Fast SCSI-2 Channels
|
|
||||||
Intel i960 RISC Processor
|
|
||||||
2MB/4MB/8MB/16MB/32MB DRAM Memory
|
|
||||||
|
|
||||||
DAC960P 1/2/3 Wide Fast SCSI-2 Channels
|
|
||||||
Intel i960 RISC Processor
|
|
||||||
2MB/4MB/8MB/16MB/32MB DRAM Memory
|
|
||||||
|
|
||||||
For the eXtremeRAID 2000/3000 and AcceleRAID 352/170/160, firmware version
|
|
||||||
6.00-01 or above is required.
|
|
||||||
|
|
||||||
For the eXtremeRAID 1100, firmware version 5.06-0-52 or above is required.
|
|
||||||
|
|
||||||
For the AcceleRAID 250, 200, and 150, firmware version 4.06-0-57 or above is
|
|
||||||
required.
|
|
||||||
|
|
||||||
For the DAC960PJ and DAC960PG, firmware version 4.06-0-00 or above is required.
|
|
||||||
|
|
||||||
For the DAC960PU, DAC960PD, DAC960PL, and DAC960P, either firmware version
|
|
||||||
3.51-0-04 or above is required (for dual Flash ROM controllers), or firmware
|
|
||||||
version 2.73-0-00 or above is required (for single Flash ROM controllers)
|
|
||||||
|
|
||||||
Please note that not all SCSI disk drives are suitable for use with DAC960
|
|
||||||
controllers, and only particular firmware versions of any given model may
|
|
||||||
actually function correctly. Similarly, not all motherboards have a BIOS that
|
|
||||||
properly initializes the AcceleRAID 250, AcceleRAID 200, AcceleRAID 150,
|
|
||||||
DAC960PJ, and DAC960PG because the Intel i960RD/RP is a multi-function device.
|
|
||||||
If in doubt, contact Mylex RAID Technical Support (mylexsup@us.ibm.com) to
|
|
||||||
verify compatibility. Mylex makes available a hard disk compatibility list at
|
|
||||||
http://www.mylex.com/support/hdcomp/hd-lists.html.
|
|
||||||
|
|
||||||
|
|
||||||
DRIVER INSTALLATION
|
|
||||||
|
|
||||||
This distribution was prepared for Linux kernel version 2.2.19 or 2.4.12.
|
|
||||||
|
|
||||||
To install the DAC960 RAID driver, you may use the following commands,
|
|
||||||
replacing "/usr/src" with wherever you keep your Linux kernel source tree:
|
|
||||||
|
|
||||||
cd /usr/src
|
|
||||||
tar -xvzf DAC960-2.2.11.tar.gz (or DAC960-2.4.11.tar.gz)
|
|
||||||
mv README.DAC960 linux/Documentation
|
|
||||||
mv DAC960.[ch] linux/drivers/block
|
|
||||||
patch -p0 < DAC960.patch (if DAC960.patch is included)
|
|
||||||
cd linux
|
|
||||||
make config
|
|
||||||
make bzImage (or zImage)
|
|
||||||
|
|
||||||
Then install "arch/x86/boot/bzImage" or "arch/x86/boot/zImage" as your
|
|
||||||
standard kernel, run lilo if appropriate, and reboot.
|
|
||||||
|
|
||||||
To create the necessary devices in /dev, the "make_rd" script included in
|
|
||||||
"DAC960-Utilities.tar.gz" from http://www.dandelion.com/Linux/ may be used.
|
|
||||||
LILO 21 and FDISK v2.9 include DAC960 support; also included in this archive
|
|
||||||
are patches to LILO 20 and FDISK v2.8 that add DAC960 support, along with
|
|
||||||
statically linked executables of LILO and FDISK. This modified version of LILO
|
|
||||||
will allow booting from a DAC960 controller and/or mounting the root file
|
|
||||||
system from a DAC960.
|
|
||||||
|
|
||||||
Red Hat Linux 6.0 and SuSE Linux 6.1 include support for Mylex PCI RAID
|
|
||||||
controllers. Installing directly onto a DAC960 may be problematic from other
|
|
||||||
Linux distributions until their installation utilities are updated.
|
|
||||||
|
|
||||||
|
|
||||||
INSTALLATION NOTES
|
|
||||||
|
|
||||||
Before installing Linux or adding DAC960 logical drives to an existing Linux
|
|
||||||
system, the controller must first be configured to provide one or more logical
|
|
||||||
drives using the BIOS Configuration Utility or DACCF. Please note that since
|
|
||||||
there are only at most 6 usable partitions on each logical drive, systems
|
|
||||||
requiring more partitions should subdivide a drive group into multiple logical
|
|
||||||
drives, each of which can have up to 6 usable partitions. Also, note that with
|
|
||||||
large disk arrays it is advisable to enable the 8GB BIOS Geometry (255/63)
|
|
||||||
rather than accepting the default 2GB BIOS Geometry (128/32); failing to so do
|
|
||||||
will cause the logical drive geometry to have more than 65535 cylinders which
|
|
||||||
will make it impossible for FDISK to be used properly. The 8GB BIOS Geometry
|
|
||||||
can be enabled by configuring the DAC960 BIOS, which is accessible via Alt-M
|
|
||||||
during the BIOS initialization sequence.
|
|
||||||
|
|
||||||
For maximum performance and the most efficient E2FSCK performance, it is
|
|
||||||
recommended that EXT2 file systems be built with a 4KB block size and 16 block
|
|
||||||
stride to match the DAC960 controller's 64KB default stripe size. The command
|
|
||||||
"mke2fs -b 4096 -R stride=16 <device>" is appropriate. Unless there will be a
|
|
||||||
large number of small files on the file systems, it is also beneficial to add
|
|
||||||
the "-i 16384" option to increase the bytes per inode parameter thereby
|
|
||||||
reducing the file system metadata. Finally, on systems that will only be run
|
|
||||||
with Linux 2.2 or later kernels it is beneficial to enable sparse superblocks
|
|
||||||
with the "-s 1" option.
|
|
||||||
|
|
||||||
|
|
||||||
DAC960 ANNOUNCEMENTS MAILING LIST
|
|
||||||
|
|
||||||
The DAC960 Announcements Mailing List provides a forum for informing Linux
|
|
||||||
users of new driver releases and other announcements regarding Linux support
|
|
||||||
for DAC960 PCI RAID Controllers. To join the mailing list, send a message to
|
|
||||||
"dac960-announce-request@dandelion.com" with the line "subscribe" in the
|
|
||||||
message body.
|
|
||||||
|
|
||||||
|
|
||||||
CONTROLLER CONFIGURATION AND STATUS MONITORING
|
|
||||||
|
|
||||||
The DAC960 RAID controllers running firmware 4.06 or above include a Background
|
|
||||||
Initialization facility so that system downtime is minimized both for initial
|
|
||||||
installation and subsequent configuration of additional storage. The BIOS
|
|
||||||
Configuration Utility (accessible via Alt-R during the BIOS initialization
|
|
||||||
sequence) is used to quickly configure the controller, and then the logical
|
|
||||||
drives that have been created are available for immediate use even while they
|
|
||||||
are still being initialized by the controller. The primary need for online
|
|
||||||
configuration and status monitoring is then to avoid system downtime when disk
|
|
||||||
drives fail and must be replaced. Mylex's online monitoring and configuration
|
|
||||||
utilities are being ported to Linux and will become available at some point in
|
|
||||||
the future. Note that with a SAF-TE (SCSI Accessed Fault-Tolerant Enclosure)
|
|
||||||
enclosure, the controller is able to rebuild failed drives automatically as
|
|
||||||
soon as a drive replacement is made available.
|
|
||||||
|
|
||||||
The primary interfaces for controller configuration and status monitoring are
|
|
||||||
special files created in the /proc/rd/... hierarchy along with the normal
|
|
||||||
system console logging mechanism. Whenever the system is operating, the DAC960
|
|
||||||
driver queries each controller for status information every 10 seconds, and
|
|
||||||
checks for additional conditions every 60 seconds. The initial status of each
|
|
||||||
controller is always available for controller N in /proc/rd/cN/initial_status,
|
|
||||||
and the current status as of the last status monitoring query is available in
|
|
||||||
/proc/rd/cN/current_status. In addition, status changes are also logged by the
|
|
||||||
driver to the system console and will appear in the log files maintained by
|
|
||||||
syslog. The progress of asynchronous rebuild or consistency check operations
|
|
||||||
is also available in /proc/rd/cN/current_status, and progress messages are
|
|
||||||
logged to the system console at most every 60 seconds.
|
|
||||||
|
|
||||||
Starting with the 2.2.3/2.0.3 versions of the driver, the status information
|
|
||||||
available in /proc/rd/cN/initial_status and /proc/rd/cN/current_status has been
|
|
||||||
augmented to include the vendor, model, revision, and serial number (if
|
|
||||||
available) for each physical device found connected to the controller:
|
|
||||||
|
|
||||||
***** DAC960 RAID Driver Version 2.2.3 of 19 August 1999 *****
|
|
||||||
Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
|
|
||||||
Configuring Mylex DAC960PRL PCI RAID Controller
|
|
||||||
Firmware Version: 4.07-0-07, Channels: 1, Memory Size: 16MB
|
|
||||||
PCI Bus: 1, Device: 4, Function: 1, I/O Address: Unassigned
|
|
||||||
PCI Address: 0xFE300000 mapped at 0xA0800000, IRQ Channel: 21
|
|
||||||
Controller Queue Depth: 128, Maximum Blocks per Command: 128
|
|
||||||
Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33
|
|
||||||
Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63
|
|
||||||
SAF-TE Enclosure Management Enabled
|
|
||||||
Physical Devices:
|
|
||||||
0:0 Vendor: IBM Model: DRVS09D Revision: 0270
|
|
||||||
Serial Number: 68016775HA
|
|
||||||
Disk Status: Online, 17928192 blocks
|
|
||||||
0:1 Vendor: IBM Model: DRVS09D Revision: 0270
|
|
||||||
Serial Number: 68004E53HA
|
|
||||||
Disk Status: Online, 17928192 blocks
|
|
||||||
0:2 Vendor: IBM Model: DRVS09D Revision: 0270
|
|
||||||
Serial Number: 13013935HA
|
|
||||||
Disk Status: Online, 17928192 blocks
|
|
||||||
0:3 Vendor: IBM Model: DRVS09D Revision: 0270
|
|
||||||
Serial Number: 13016897HA
|
|
||||||
Disk Status: Online, 17928192 blocks
|
|
||||||
0:4 Vendor: IBM Model: DRVS09D Revision: 0270
|
|
||||||
Serial Number: 68019905HA
|
|
||||||
Disk Status: Online, 17928192 blocks
|
|
||||||
0:5 Vendor: IBM Model: DRVS09D Revision: 0270
|
|
||||||
Serial Number: 68012753HA
|
|
||||||
Disk Status: Online, 17928192 blocks
|
|
||||||
0:6 Vendor: ESG-SHV Model: SCA HSBP M6 Revision: 0.61
|
|
||||||
Logical Drives:
|
|
||||||
/dev/rd/c0d0: RAID-5, Online, 89640960 blocks, Write Thru
|
|
||||||
No Rebuild or Consistency Check in Progress
|
|
||||||
|
|
||||||
To simplify the monitoring process for custom software, the special file
|
|
||||||
/proc/rd/status returns "OK" when all DAC960 controllers in the system are
|
|
||||||
operating normally and no failures have occurred, or "ALERT" if any logical
|
|
||||||
drives are offline or critical or any non-standby physical drives are dead.
|
|
||||||
|
|
||||||
Configuration commands for controller N are available via the special file
|
|
||||||
/proc/rd/cN/user_command. A human readable command can be written to this
|
|
||||||
special file to initiate a configuration operation, and the results of the
|
|
||||||
operation can then be read back from the special file in addition to being
|
|
||||||
logged to the system console. The shell command sequence
|
|
||||||
|
|
||||||
echo "<configuration-command>" > /proc/rd/c0/user_command
|
|
||||||
cat /proc/rd/c0/user_command
|
|
||||||
|
|
||||||
is typically used to execute configuration commands. The configuration
|
|
||||||
commands are:
|
|
||||||
|
|
||||||
flush-cache
|
|
||||||
|
|
||||||
The "flush-cache" command flushes the controller's cache. The system
|
|
||||||
automatically flushes the cache at shutdown or if the driver module is
|
|
||||||
unloaded, so this command is only needed to be certain a write back cache
|
|
||||||
is flushed to disk before the system is powered off by a command to a UPS.
|
|
||||||
Note that the flush-cache command also stops an asynchronous rebuild or
|
|
||||||
consistency check, so it should not be used except when the system is being
|
|
||||||
halted.
|
|
||||||
|
|
||||||
kill <channel>:<target-id>
|
|
||||||
|
|
||||||
The "kill" command marks the physical drive <channel>:<target-id> as DEAD.
|
|
||||||
This command is provided primarily for testing, and should not be used
|
|
||||||
during normal system operation.
|
|
||||||
|
|
||||||
make-online <channel>:<target-id>
|
|
||||||
|
|
||||||
The "make-online" command changes the physical drive <channel>:<target-id>
|
|
||||||
from status DEAD to status ONLINE. In cases where multiple physical drives
|
|
||||||
have been killed simultaneously, this command may be used to bring all but
|
|
||||||
one of them back online, after which a rebuild to the final drive is
|
|
||||||
necessary.
|
|
||||||
|
|
||||||
Warning: make-online should only be used on a dead physical drive that is
|
|
||||||
an active part of a drive group, never on a standby drive. The command
|
|
||||||
should never be used on a dead drive that is part of a critical logical
|
|
||||||
drive; rebuild should be used if only a single drive is dead.
|
|
||||||
|
|
||||||
make-standby <channel>:<target-id>
|
|
||||||
|
|
||||||
The "make-standby" command changes physical drive <channel>:<target-id>
|
|
||||||
from status DEAD to status STANDBY. It should only be used in cases where
|
|
||||||
a dead drive was replaced after an automatic rebuild was performed onto a
|
|
||||||
standby drive. It cannot be used to add a standby drive to the controller
|
|
||||||
configuration if one was not created initially; the BIOS Configuration
|
|
||||||
Utility must be used for that currently.
|
|
||||||
|
|
||||||
rebuild <channel>:<target-id>
|
|
||||||
|
|
||||||
The "rebuild" command initiates an asynchronous rebuild onto physical drive
|
|
||||||
<channel>:<target-id>. It should only be used when a dead drive has been
|
|
||||||
replaced.
|
|
||||||
|
|
||||||
check-consistency <logical-drive-number>
|
|
||||||
|
|
||||||
The "check-consistency" command initiates an asynchronous consistency check
|
|
||||||
of <logical-drive-number> with automatic restoration. It can be used
|
|
||||||
whenever it is desired to verify the consistency of the redundancy
|
|
||||||
information.
|
|
||||||
|
|
||||||
cancel-rebuild
|
|
||||||
cancel-consistency-check
|
|
||||||
|
|
||||||
The "cancel-rebuild" and "cancel-consistency-check" commands cancel any
|
|
||||||
rebuild or consistency check operations previously initiated.
|
|
||||||
|
|
||||||
|
|
||||||
EXAMPLE I - DRIVE FAILURE WITHOUT A STANDBY DRIVE
|
|
||||||
|
|
||||||
The following annotated logs demonstrate the controller configuration and and
|
|
||||||
online status monitoring capabilities of the Linux DAC960 Driver. The test
|
|
||||||
configuration comprises 6 1GB Quantum Atlas I disk drives on two channels of a
|
|
||||||
DAC960PJ controller. The physical drives are configured into a single drive
|
|
||||||
group without a standby drive, and the drive group has been configured into two
|
|
||||||
logical drives, one RAID-5 and one RAID-6. Note that these logs are from an
|
|
||||||
earlier version of the driver and the messages have changed somewhat with newer
|
|
||||||
releases, but the functionality remains similar. First, here is the current
|
|
||||||
status of the RAID configuration:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
|
|
||||||
***** DAC960 RAID Driver Version 2.0.0 of 23 March 1999 *****
|
|
||||||
Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
|
|
||||||
Configuring Mylex DAC960PJ PCI RAID Controller
|
|
||||||
Firmware Version: 4.06-0-08, Channels: 3, Memory Size: 8MB
|
|
||||||
PCI Bus: 0, Device: 19, Function: 1, I/O Address: Unassigned
|
|
||||||
PCI Address: 0xFD4FC000 mapped at 0x8807000, IRQ Channel: 9
|
|
||||||
Controller Queue Depth: 128, Maximum Blocks per Command: 128
|
|
||||||
Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33
|
|
||||||
Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63
|
|
||||||
Physical Devices:
|
|
||||||
0:1 - Disk: Online, 2201600 blocks
|
|
||||||
0:2 - Disk: Online, 2201600 blocks
|
|
||||||
0:3 - Disk: Online, 2201600 blocks
|
|
||||||
1:1 - Disk: Online, 2201600 blocks
|
|
||||||
1:2 - Disk: Online, 2201600 blocks
|
|
||||||
1:3 - Disk: Online, 2201600 blocks
|
|
||||||
Logical Drives:
|
|
||||||
/dev/rd/c0d0: RAID-5, Online, 5498880 blocks, Write Thru
|
|
||||||
/dev/rd/c0d1: RAID-6, Online, 3305472 blocks, Write Thru
|
|
||||||
No Rebuild or Consistency Check in Progress
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/status
|
|
||||||
OK
|
|
||||||
|
|
||||||
The above messages indicate that everything is healthy, and /proc/rd/status
|
|
||||||
returns "OK" indicating that there are no problems with any DAC960 controller
|
|
||||||
in the system. For demonstration purposes, while I/O is active Physical Drive
|
|
||||||
1:1 is now disconnected, simulating a drive failure. The failure is noted by
|
|
||||||
the driver within 10 seconds of the controller's having detected it, and the
|
|
||||||
driver logs the following console status messages indicating that Logical
|
|
||||||
Drives 0 and 1 are now CRITICAL as a result of Physical Drive 1:1 being DEAD:
|
|
||||||
|
|
||||||
DAC960#0: Physical Drive 1:2 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02
|
|
||||||
DAC960#0: Physical Drive 1:3 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02
|
|
||||||
DAC960#0: Physical Drive 1:1 killed because of timeout on SCSI command
|
|
||||||
DAC960#0: Physical Drive 1:1 is now DEAD
|
|
||||||
DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now CRITICAL
|
|
||||||
DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now CRITICAL
|
|
||||||
|
|
||||||
The Sense Keys logged here are just Check Condition / Unit Attention conditions
|
|
||||||
arising from a SCSI bus reset that is forced by the controller during its error
|
|
||||||
recovery procedures. Concurrently with the above, the driver status available
|
|
||||||
from /proc/rd also reflects the drive failure. The status message in
|
|
||||||
/proc/rd/status has changed from "OK" to "ALERT":
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/status
|
|
||||||
ALERT
|
|
||||||
|
|
||||||
and /proc/rd/c0/current_status has been updated:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
|
|
||||||
...
|
|
||||||
Physical Devices:
|
|
||||||
0:1 - Disk: Online, 2201600 blocks
|
|
||||||
0:2 - Disk: Online, 2201600 blocks
|
|
||||||
0:3 - Disk: Online, 2201600 blocks
|
|
||||||
1:1 - Disk: Dead, 2201600 blocks
|
|
||||||
1:2 - Disk: Online, 2201600 blocks
|
|
||||||
1:3 - Disk: Online, 2201600 blocks
|
|
||||||
Logical Drives:
|
|
||||||
/dev/rd/c0d0: RAID-5, Critical, 5498880 blocks, Write Thru
|
|
||||||
/dev/rd/c0d1: RAID-6, Critical, 3305472 blocks, Write Thru
|
|
||||||
No Rebuild or Consistency Check in Progress
|
|
||||||
|
|
||||||
Since there are no standby drives configured, the system can continue to access
|
|
||||||
the logical drives in a performance degraded mode until the failed drive is
|
|
||||||
replaced and a rebuild operation completed to restore the redundancy of the
|
|
||||||
logical drives. Once Physical Drive 1:1 is replaced with a properly
|
|
||||||
functioning drive, or if the physical drive was killed without having failed
|
|
||||||
(e.g., due to electrical problems on the SCSI bus), the user can instruct the
|
|
||||||
controller to initiate a rebuild operation onto the newly replaced drive:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# echo "rebuild 1:1" > /proc/rd/c0/user_command
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/c0/user_command
|
|
||||||
Rebuild of Physical Drive 1:1 Initiated
|
|
||||||
|
|
||||||
The echo command instructs the controller to initiate an asynchronous rebuild
|
|
||||||
operation onto Physical Drive 1:1, and the status message that results from the
|
|
||||||
operation is then available for reading from /proc/rd/c0/user_command, as well
|
|
||||||
as being logged to the console by the driver.
|
|
||||||
|
|
||||||
Within 10 seconds of this command the driver logs the initiation of the
|
|
||||||
asynchronous rebuild operation:
|
|
||||||
|
|
||||||
DAC960#0: Rebuild of Physical Drive 1:1 Initiated
|
|
||||||
DAC960#0: Physical Drive 1:1 Error Log: Sense Key = 6, ASC = 29, ASCQ = 01
|
|
||||||
DAC960#0: Physical Drive 1:1 is now WRITE-ONLY
|
|
||||||
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 1% completed
|
|
||||||
|
|
||||||
and /proc/rd/c0/current_status is updated:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
|
|
||||||
...
|
|
||||||
Physical Devices:
|
|
||||||
0:1 - Disk: Online, 2201600 blocks
|
|
||||||
0:2 - Disk: Online, 2201600 blocks
|
|
||||||
0:3 - Disk: Online, 2201600 blocks
|
|
||||||
1:1 - Disk: Write-Only, 2201600 blocks
|
|
||||||
1:2 - Disk: Online, 2201600 blocks
|
|
||||||
1:3 - Disk: Online, 2201600 blocks
|
|
||||||
Logical Drives:
|
|
||||||
/dev/rd/c0d0: RAID-5, Critical, 5498880 blocks, Write Thru
|
|
||||||
/dev/rd/c0d1: RAID-6, Critical, 3305472 blocks, Write Thru
|
|
||||||
Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 6% completed
|
|
||||||
|
|
||||||
As the rebuild progresses, the current status in /proc/rd/c0/current_status is
|
|
||||||
updated every 10 seconds:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
|
|
||||||
...
|
|
||||||
Physical Devices:
|
|
||||||
0:1 - Disk: Online, 2201600 blocks
|
|
||||||
0:2 - Disk: Online, 2201600 blocks
|
|
||||||
0:3 - Disk: Online, 2201600 blocks
|
|
||||||
1:1 - Disk: Write-Only, 2201600 blocks
|
|
||||||
1:2 - Disk: Online, 2201600 blocks
|
|
||||||
1:3 - Disk: Online, 2201600 blocks
|
|
||||||
Logical Drives:
|
|
||||||
/dev/rd/c0d0: RAID-5, Critical, 5498880 blocks, Write Thru
|
|
||||||
/dev/rd/c0d1: RAID-6, Critical, 3305472 blocks, Write Thru
|
|
||||||
Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 15% completed
|
|
||||||
|
|
||||||
and every minute a progress message is logged to the console by the driver:
|
|
||||||
|
|
||||||
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 32% completed
|
|
||||||
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 63% completed
|
|
||||||
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 94% completed
|
|
||||||
DAC960#0: Rebuild in Progress: Logical Drive 1 (/dev/rd/c0d1) 94% completed
|
|
||||||
|
|
||||||
Finally, the rebuild completes successfully. The driver logs the status of the
|
|
||||||
logical and physical drives and the rebuild completion:
|
|
||||||
|
|
||||||
DAC960#0: Rebuild Completed Successfully
|
|
||||||
DAC960#0: Physical Drive 1:1 is now ONLINE
|
|
||||||
DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now ONLINE
|
|
||||||
DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now ONLINE
|
|
||||||
|
|
||||||
/proc/rd/c0/current_status is updated:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
|
|
||||||
...
|
|
||||||
Physical Devices:
|
|
||||||
0:1 - Disk: Online, 2201600 blocks
|
|
||||||
0:2 - Disk: Online, 2201600 blocks
|
|
||||||
0:3 - Disk: Online, 2201600 blocks
|
|
||||||
1:1 - Disk: Online, 2201600 blocks
|
|
||||||
1:2 - Disk: Online, 2201600 blocks
|
|
||||||
1:3 - Disk: Online, 2201600 blocks
|
|
||||||
Logical Drives:
|
|
||||||
/dev/rd/c0d0: RAID-5, Online, 5498880 blocks, Write Thru
|
|
||||||
/dev/rd/c0d1: RAID-6, Online, 3305472 blocks, Write Thru
|
|
||||||
Rebuild Completed Successfully
|
|
||||||
|
|
||||||
and /proc/rd/status indicates that everything is healthy once again:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/status
|
|
||||||
OK
|
|
||||||
|
|
||||||
|
|
||||||
EXAMPLE II - DRIVE FAILURE WITH A STANDBY DRIVE
|
|
||||||
|
|
||||||
The following annotated logs demonstrate the controller configuration and and
|
|
||||||
online status monitoring capabilities of the Linux DAC960 Driver. The test
|
|
||||||
configuration comprises 6 1GB Quantum Atlas I disk drives on two channels of a
|
|
||||||
DAC960PJ controller. The physical drives are configured into a single drive
|
|
||||||
group with a standby drive, and the drive group has been configured into two
|
|
||||||
logical drives, one RAID-5 and one RAID-6. Note that these logs are from an
|
|
||||||
earlier version of the driver and the messages have changed somewhat with newer
|
|
||||||
releases, but the functionality remains similar. First, here is the current
|
|
||||||
status of the RAID configuration:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
|
|
||||||
***** DAC960 RAID Driver Version 2.0.0 of 23 March 1999 *****
|
|
||||||
Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
|
|
||||||
Configuring Mylex DAC960PJ PCI RAID Controller
|
|
||||||
Firmware Version: 4.06-0-08, Channels: 3, Memory Size: 8MB
|
|
||||||
PCI Bus: 0, Device: 19, Function: 1, I/O Address: Unassigned
|
|
||||||
PCI Address: 0xFD4FC000 mapped at 0x8807000, IRQ Channel: 9
|
|
||||||
Controller Queue Depth: 128, Maximum Blocks per Command: 128
|
|
||||||
Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33
|
|
||||||
Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63
|
|
||||||
Physical Devices:
|
|
||||||
0:1 - Disk: Online, 2201600 blocks
|
|
||||||
0:2 - Disk: Online, 2201600 blocks
|
|
||||||
0:3 - Disk: Online, 2201600 blocks
|
|
||||||
1:1 - Disk: Online, 2201600 blocks
|
|
||||||
1:2 - Disk: Online, 2201600 blocks
|
|
||||||
1:3 - Disk: Standby, 2201600 blocks
|
|
||||||
Logical Drives:
|
|
||||||
/dev/rd/c0d0: RAID-5, Online, 4399104 blocks, Write Thru
|
|
||||||
/dev/rd/c0d1: RAID-6, Online, 2754560 blocks, Write Thru
|
|
||||||
No Rebuild or Consistency Check in Progress
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/status
|
|
||||||
OK
|
|
||||||
|
|
||||||
The above messages indicate that everything is healthy, and /proc/rd/status
|
|
||||||
returns "OK" indicating that there are no problems with any DAC960 controller
|
|
||||||
in the system. For demonstration purposes, while I/O is active Physical Drive
|
|
||||||
1:2 is now disconnected, simulating a drive failure. The failure is noted by
|
|
||||||
the driver within 10 seconds of the controller's having detected it, and the
|
|
||||||
driver logs the following console status messages:
|
|
||||||
|
|
||||||
DAC960#0: Physical Drive 1:1 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02
|
|
||||||
DAC960#0: Physical Drive 1:3 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02
|
|
||||||
DAC960#0: Physical Drive 1:2 killed because of timeout on SCSI command
|
|
||||||
DAC960#0: Physical Drive 1:2 is now DEAD
|
|
||||||
DAC960#0: Physical Drive 1:2 killed because it was removed
|
|
||||||
DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now CRITICAL
|
|
||||||
DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now CRITICAL
|
|
||||||
|
|
||||||
Since a standby drive is configured, the controller automatically begins
|
|
||||||
rebuilding onto the standby drive:
|
|
||||||
|
|
||||||
DAC960#0: Physical Drive 1:3 is now WRITE-ONLY
|
|
||||||
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 4% completed
|
|
||||||
|
|
||||||
Concurrently with the above, the driver status available from /proc/rd also
|
|
||||||
reflects the drive failure and automatic rebuild. The status message in
|
|
||||||
/proc/rd/status has changed from "OK" to "ALERT":
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/status
|
|
||||||
ALERT
|
|
||||||
|
|
||||||
and /proc/rd/c0/current_status has been updated:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
|
|
||||||
...
|
|
||||||
Physical Devices:
|
|
||||||
0:1 - Disk: Online, 2201600 blocks
|
|
||||||
0:2 - Disk: Online, 2201600 blocks
|
|
||||||
0:3 - Disk: Online, 2201600 blocks
|
|
||||||
1:1 - Disk: Online, 2201600 blocks
|
|
||||||
1:2 - Disk: Dead, 2201600 blocks
|
|
||||||
1:3 - Disk: Write-Only, 2201600 blocks
|
|
||||||
Logical Drives:
|
|
||||||
/dev/rd/c0d0: RAID-5, Critical, 4399104 blocks, Write Thru
|
|
||||||
/dev/rd/c0d1: RAID-6, Critical, 2754560 blocks, Write Thru
|
|
||||||
Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 4% completed
|
|
||||||
|
|
||||||
As the rebuild progresses, the current status in /proc/rd/c0/current_status is
|
|
||||||
updated every 10 seconds:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
|
|
||||||
...
|
|
||||||
Physical Devices:
|
|
||||||
0:1 - Disk: Online, 2201600 blocks
|
|
||||||
0:2 - Disk: Online, 2201600 blocks
|
|
||||||
0:3 - Disk: Online, 2201600 blocks
|
|
||||||
1:1 - Disk: Online, 2201600 blocks
|
|
||||||
1:2 - Disk: Dead, 2201600 blocks
|
|
||||||
1:3 - Disk: Write-Only, 2201600 blocks
|
|
||||||
Logical Drives:
|
|
||||||
/dev/rd/c0d0: RAID-5, Critical, 4399104 blocks, Write Thru
|
|
||||||
/dev/rd/c0d1: RAID-6, Critical, 2754560 blocks, Write Thru
|
|
||||||
Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 40% completed
|
|
||||||
|
|
||||||
and every minute a progress message is logged on the console by the driver:
|
|
||||||
|
|
||||||
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 40% completed
|
|
||||||
DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 76% completed
|
|
||||||
DAC960#0: Rebuild in Progress: Logical Drive 1 (/dev/rd/c0d1) 66% completed
|
|
||||||
DAC960#0: Rebuild in Progress: Logical Drive 1 (/dev/rd/c0d1) 84% completed
|
|
||||||
|
|
||||||
Finally, the rebuild completes successfully. The driver logs the status of the
|
|
||||||
logical and physical drives and the rebuild completion:
|
|
||||||
|
|
||||||
DAC960#0: Rebuild Completed Successfully
|
|
||||||
DAC960#0: Physical Drive 1:3 is now ONLINE
|
|
||||||
DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now ONLINE
|
|
||||||
DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now ONLINE
|
|
||||||
|
|
||||||
/proc/rd/c0/current_status is updated:
|
|
||||||
|
|
||||||
***** DAC960 RAID Driver Version 2.0.0 of 23 March 1999 *****
|
|
||||||
Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
|
|
||||||
Configuring Mylex DAC960PJ PCI RAID Controller
|
|
||||||
Firmware Version: 4.06-0-08, Channels: 3, Memory Size: 8MB
|
|
||||||
PCI Bus: 0, Device: 19, Function: 1, I/O Address: Unassigned
|
|
||||||
PCI Address: 0xFD4FC000 mapped at 0x8807000, IRQ Channel: 9
|
|
||||||
Controller Queue Depth: 128, Maximum Blocks per Command: 128
|
|
||||||
Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33
|
|
||||||
Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63
|
|
||||||
Physical Devices:
|
|
||||||
0:1 - Disk: Online, 2201600 blocks
|
|
||||||
0:2 - Disk: Online, 2201600 blocks
|
|
||||||
0:3 - Disk: Online, 2201600 blocks
|
|
||||||
1:1 - Disk: Online, 2201600 blocks
|
|
||||||
1:2 - Disk: Dead, 2201600 blocks
|
|
||||||
1:3 - Disk: Online, 2201600 blocks
|
|
||||||
Logical Drives:
|
|
||||||
/dev/rd/c0d0: RAID-5, Online, 4399104 blocks, Write Thru
|
|
||||||
/dev/rd/c0d1: RAID-6, Online, 2754560 blocks, Write Thru
|
|
||||||
Rebuild Completed Successfully
|
|
||||||
|
|
||||||
and /proc/rd/status indicates that everything is healthy once again:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/status
|
|
||||||
OK
|
|
||||||
|
|
||||||
Note that the absence of a viable standby drive does not create an "ALERT"
|
|
||||||
status. Once dead Physical Drive 1:2 has been replaced, the controller must be
|
|
||||||
told that this has occurred and that the newly replaced drive should become the
|
|
||||||
new standby drive:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# echo "make-standby 1:2" > /proc/rd/c0/user_command
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/c0/user_command
|
|
||||||
Make Standby of Physical Drive 1:2 Succeeded
|
|
||||||
|
|
||||||
The echo command instructs the controller to make Physical Drive 1:2 into a
|
|
||||||
standby drive, and the status message that results from the operation is then
|
|
||||||
available for reading from /proc/rd/c0/user_command, as well as being logged to
|
|
||||||
the console by the driver. Within 60 seconds of this command the driver logs:
|
|
||||||
|
|
||||||
DAC960#0: Physical Drive 1:2 Error Log: Sense Key = 6, ASC = 29, ASCQ = 01
|
|
||||||
DAC960#0: Physical Drive 1:2 is now STANDBY
|
|
||||||
DAC960#0: Make Standby of Physical Drive 1:2 Succeeded
|
|
||||||
|
|
||||||
and /proc/rd/c0/current_status is updated:
|
|
||||||
|
|
||||||
gwynedd:/u/lnz# cat /proc/rd/c0/current_status
|
|
||||||
...
|
|
||||||
Physical Devices:
|
|
||||||
0:1 - Disk: Online, 2201600 blocks
|
|
||||||
0:2 - Disk: Online, 2201600 blocks
|
|
||||||
0:3 - Disk: Online, 2201600 blocks
|
|
||||||
1:1 - Disk: Online, 2201600 blocks
|
|
||||||
1:2 - Disk: Standby, 2201600 blocks
|
|
||||||
1:3 - Disk: Online, 2201600 blocks
|
|
||||||
Logical Drives:
|
|
||||||
/dev/rd/c0d0: RAID-5, Online, 4399104 blocks, Write Thru
|
|
||||||
/dev/rd/c0d1: RAID-6, Online, 2754560 blocks, Write Thru
|
|
||||||
Rebuild Completed Successfully
|
|
File diff suppressed because it is too large
Load Diff
File diff suppressed because it is too large
Load Diff
|
@ -121,18 +121,6 @@ source "drivers/block/mtip32xx/Kconfig"
|
||||||
|
|
||||||
source "drivers/block/zram/Kconfig"
|
source "drivers/block/zram/Kconfig"
|
||||||
|
|
||||||
config BLK_DEV_DAC960
|
|
||||||
tristate "Mylex DAC960/DAC1100 PCI RAID Controller support"
|
|
||||||
depends on PCI
|
|
||||||
help
|
|
||||||
This driver adds support for the Mylex DAC960, AcceleRAID, and
|
|
||||||
eXtremeRAID PCI RAID controllers. See the file
|
|
||||||
<file:Documentation/blockdev/README.DAC960> for further information
|
|
||||||
about this driver.
|
|
||||||
|
|
||||||
To compile this driver as a module, choose M here: the
|
|
||||||
module will be called DAC960.
|
|
||||||
|
|
||||||
config BLK_DEV_UMEM
|
config BLK_DEV_UMEM
|
||||||
tristate "Micro Memory MM5415 Battery Backed RAM support"
|
tristate "Micro Memory MM5415 Battery Backed RAM support"
|
||||||
depends on PCI
|
depends on PCI
|
||||||
|
|
|
@ -16,7 +16,6 @@ obj-$(CONFIG_ATARI_FLOPPY) += ataflop.o
|
||||||
obj-$(CONFIG_AMIGA_Z2RAM) += z2ram.o
|
obj-$(CONFIG_AMIGA_Z2RAM) += z2ram.o
|
||||||
obj-$(CONFIG_BLK_DEV_RAM) += brd.o
|
obj-$(CONFIG_BLK_DEV_RAM) += brd.o
|
||||||
obj-$(CONFIG_BLK_DEV_LOOP) += loop.o
|
obj-$(CONFIG_BLK_DEV_LOOP) += loop.o
|
||||||
obj-$(CONFIG_BLK_DEV_DAC960) += DAC960.o
|
|
||||||
obj-$(CONFIG_XILINX_SYSACE) += xsysace.o
|
obj-$(CONFIG_XILINX_SYSACE) += xsysace.o
|
||||||
obj-$(CONFIG_CDROM_PKTCDVD) += pktcdvd.o
|
obj-$(CONFIG_CDROM_PKTCDVD) += pktcdvd.o
|
||||||
obj-$(CONFIG_SUNVDC) += sunvdc.o
|
obj-$(CONFIG_SUNVDC) += sunvdc.o
|
||||||
|
|