linux-brain/drivers/thunderbolt/nhi.h

78 lines
2.5 KiB
C
Raw Normal View History

License cleanup: add SPDX GPL-2.0 license identifier to files with no license Many source files in the tree are missing licensing information, which makes it harder for compliance tools to determine the correct license. By default all files without license information are under the default license of the kernel, which is GPL version 2. Update the files which contain no license information with the 'GPL-2.0' SPDX license identifier. The SPDX identifier is a legally binding shorthand, which can be used instead of the full boiler plate text. This patch is based on work done by Thomas Gleixner and Kate Stewart and Philippe Ombredanne. How this work was done: Patches were generated and checked against linux-4.14-rc6 for a subset of the use cases: - file had no licensing information it it. - file was a */uapi/* one with no licensing information in it, - file was a */uapi/* one with existing licensing information, Further patches will be generated in subsequent months to fix up cases where non-standard license headers were used, and references to license had to be inferred by heuristics based on keywords. The analysis to determine which SPDX License Identifier to be applied to a file was done in a spreadsheet of side by side results from of the output of two independent scanners (ScanCode & Windriver) producing SPDX tag:value files created by Philippe Ombredanne. Philippe prepared the base worksheet, and did an initial spot review of a few 1000 files. The 4.13 kernel was the starting point of the analysis with 60,537 files assessed. Kate Stewart did a file by file comparison of the scanner results in the spreadsheet to determine which SPDX license identifier(s) to be applied to the file. She confirmed any determination that was not immediately clear with lawyers working with the Linux Foundation. Criteria used to select files for SPDX license identifier tagging was: - Files considered eligible had to be source code files. - Make and config files were included as candidates if they contained >5 lines of source - File already had some variant of a license header in it (even if <5 lines). All documentation files were explicitly excluded. The following heuristics were used to determine which SPDX license identifiers to apply. - when both scanners couldn't find any license traces, file was considered to have no license information in it, and the top level COPYING file license applied. For non */uapi/* files that summary was: SPDX license identifier # files ---------------------------------------------------|------- GPL-2.0 11139 and resulted in the first patch in this series. If that file was a */uapi/* path one, it was "GPL-2.0 WITH Linux-syscall-note" otherwise it was "GPL-2.0". Results of that was: SPDX license identifier # files ---------------------------------------------------|------- GPL-2.0 WITH Linux-syscall-note 930 and resulted in the second patch in this series. - if a file had some form of licensing information in it, and was one of the */uapi/* ones, it was denoted with the Linux-syscall-note if any GPL family license was found in the file or had no licensing in it (per prior point). Results summary: SPDX license identifier # files ---------------------------------------------------|------ GPL-2.0 WITH Linux-syscall-note 270 GPL-2.0+ WITH Linux-syscall-note 169 ((GPL-2.0 WITH Linux-syscall-note) OR BSD-2-Clause) 21 ((GPL-2.0 WITH Linux-syscall-note) OR BSD-3-Clause) 17 LGPL-2.1+ WITH Linux-syscall-note 15 GPL-1.0+ WITH Linux-syscall-note 14 ((GPL-2.0+ WITH Linux-syscall-note) OR BSD-3-Clause) 5 LGPL-2.0+ WITH Linux-syscall-note 4 LGPL-2.1 WITH Linux-syscall-note 3 ((GPL-2.0 WITH Linux-syscall-note) OR MIT) 3 ((GPL-2.0 WITH Linux-syscall-note) AND MIT) 1 and that resulted in the third patch in this series. - when the two scanners agreed on the detected license(s), that became the concluded license(s). - when there was disagreement between the two scanners (one detected a license but the other didn't, or they both detected different licenses) a manual inspection of the file occurred. - In most cases a manual inspection of the information in the file resulted in a clear resolution of the license that should apply (and which scanner probably needed to revisit its heuristics). - When it was not immediately clear, the license identifier was confirmed with lawyers working with the Linux Foundation. - If there was any question as to the appropriate license identifier, the file was flagged for further research and to be revisited later in time. In total, over 70 hours of logged manual review was done on the spreadsheet to determine the SPDX license identifiers to apply to the source files by Kate, Philippe, Thomas and, in some cases, confirmation by lawyers working with the Linux Foundation. Kate also obtained a third independent scan of the 4.13 code base from FOSSology, and compared selected files where the other two scanners disagreed against that SPDX file, to see if there was new insights. The Windriver scanner is based on an older version of FOSSology in part, so they are related. Thomas did random spot checks in about 500 files from the spreadsheets for the uapi headers and agreed with SPDX license identifier in the files he inspected. For the non-uapi files Thomas did random spot checks in about 15000 files. In initial set of patches against 4.14-rc6, 3 files were found to have copy/paste license identifier errors, and have been fixed to reflect the correct identifier. Additionally Philippe spent 10 hours this week doing a detailed manual inspection and review of the 12,461 patched files from the initial patch version early this week with: - a full scancode scan run, collecting the matched texts, detected license ids and scores - reviewing anything where there was a license detected (about 500+ files) to ensure that the applied SPDX license was correct - reviewing anything where there was no detection but the patch license was not GPL-2.0 WITH Linux-syscall-note to ensure that the applied SPDX license was correct This produced a worksheet with 20 files needing minor correction. This worksheet was then exported into 3 different .csv files for the different types of files to be modified. These .csv files were then reviewed by Greg. Thomas wrote a script to parse the csv files and add the proper SPDX tag to the file, in the format that the file expected. This script was further refined by Greg based on the output to detect more types of files automatically and to distinguish between header and source .c files (which need different comment types.) Finally Greg ran the script using the .csv files to generate the patches. Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org> Reviewed-by: Philippe Ombredanne <pombredanne@nexb.com> Reviewed-by: Thomas Gleixner <tglx@linutronix.de> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2017-11-01 23:07:57 +09:00
/* SPDX-License-Identifier: GPL-2.0 */
/*
* Thunderbolt driver - NHI driver
*
* Copyright (c) 2014 Andreas Noever <andreas.noever@gmail.com>
* Copyright (C) 2018, Intel Corporation
*/
#ifndef DSL3510_H_
#define DSL3510_H_
#include <linux/thunderbolt.h>
enum nhi_fw_mode {
NHI_FW_SAFE_MODE,
NHI_FW_AUTH_MODE,
NHI_FW_EP_MODE,
NHI_FW_CM_MODE,
};
enum nhi_mailbox_cmd {
NHI_MAILBOX_SAVE_DEVS = 0x05,
thunderbolt: Add support for host and device NVM firmware upgrade Starting from Intel Falcon Ridge the NVM firmware can be upgraded by using DMA configuration based mailbox commands. If we detect that the host or device (device support starts from Intel Alpine Ridge) has the DMA configuration based mailbox we expose NVM information to the userspace as two separate Linux NVMem devices: nvm_active and nvm_non_active. The former is read-only portion of the active NVM which firmware upgrade tools can be use to find out suitable NVM image if the device identification strings are not enough. The latter is write-only portion where the new NVM image is to be written by the userspace. It is up to the userspace to find out right NVM image (the kernel does very minimal validation). The ICM firmware itself authenticates the new NVM firmware and fails the operation if it is not what is expected. We also expose two new sysfs files per each switch: nvm_version and nvm_authenticate which can be used to read the active NVM version and start the upgrade process. We also introduce safe mode which is the mode a switch goes when it does not have properly authenticated firmware. In this mode the switch only accepts a couple of commands including flashing a new NVM firmware image and triggering power cycle. This code is based on the work done by Amir Levy and Michael Jamet. Signed-off-by: Michael Jamet <michael.jamet@intel.com> Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com> Reviewed-by: Yehezkel Bernat <yehezkel.bernat@intel.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Andreas Noever <andreas.noever@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2017-06-06 21:25:17 +09:00
NHI_MAILBOX_DISCONNECT_PCIE_PATHS = 0x06,
NHI_MAILBOX_DRV_UNLOADS = 0x07,
thunderbolt: Add support for XDomain discovery protocol When two hosts are connected over a Thunderbolt cable, there is a protocol they can use to communicate capabilities supported by the host. The discovery protocol uses automatically configured control channel (ring 0) and is build on top of request/response transactions using special XDomain primitives provided by the Thunderbolt base protocol. The capabilities consists of a root directory block of basic properties used for identification of the host, and then there can be zero or more directories each describing a Thunderbolt service and its capabilities. Once both sides have discovered what is supported the two hosts can setup high-speed DMA paths and transfer data to the other side using whatever protocol was agreed based on the properties. The software protocol used to communicate which DMA paths to enable is service specific. This patch adds support for the XDomain discovery protocol to the Thunderbolt bus. We model each remote host connection as a Linux XDomain device. For each Thunderbolt service found supported on the XDomain device, we create Linux Thunderbolt service device which Thunderbolt service drivers can then bind to based on the protocol identification information retrieved from the property directory describing the service. This code is based on the work done by Amir Levy and Michael Jamet. Signed-off-by: Michael Jamet <michael.jamet@intel.com> Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com> Reviewed-by: Yehezkel Bernat <yehezkel.bernat@intel.com> Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2017-10-02 19:38:34 +09:00
NHI_MAILBOX_DISCONNECT_PA = 0x10,
NHI_MAILBOX_DISCONNECT_PB = 0x11,
NHI_MAILBOX_ALLOW_ALL_DEVS = 0x23,
};
int nhi_mailbox_cmd(struct tb_nhi *nhi, enum nhi_mailbox_cmd cmd, u32 data);
enum nhi_fw_mode nhi_mailbox_mode(struct tb_nhi *nhi);
/**
* struct tb_nhi_ops - NHI specific optional operations
* @init: NHI specific initialization
* @suspend_noirq: NHI specific suspend_noirq hook
* @resume_noirq: NHI specific resume_noirq hook
* @runtime_suspend: NHI specific runtime_suspend hook
* @runtime_resume: NHI specific runtime_resume hook
* @shutdown: NHI specific shutdown
*/
struct tb_nhi_ops {
int (*init)(struct tb_nhi *nhi);
int (*suspend_noirq)(struct tb_nhi *nhi, bool wakeup);
int (*resume_noirq)(struct tb_nhi *nhi);
int (*runtime_suspend)(struct tb_nhi *nhi);
int (*runtime_resume)(struct tb_nhi *nhi);
void (*shutdown)(struct tb_nhi *nhi);
};
extern const struct tb_nhi_ops icl_nhi_ops;
/*
* PCI IDs used in this driver from Win Ridge forward. There is no
* need for the PCI quirk anymore as we will use ICM also on Apple
* hardware.
*/
#define PCI_DEVICE_ID_INTEL_WIN_RIDGE_2C_NHI 0x157d
#define PCI_DEVICE_ID_INTEL_WIN_RIDGE_2C_BRIDGE 0x157e
#define PCI_DEVICE_ID_INTEL_ALPINE_RIDGE_LP_NHI 0x15bf
#define PCI_DEVICE_ID_INTEL_ALPINE_RIDGE_LP_BRIDGE 0x15c0
#define PCI_DEVICE_ID_INTEL_ALPINE_RIDGE_C_4C_NHI 0x15d2
#define PCI_DEVICE_ID_INTEL_ALPINE_RIDGE_C_4C_BRIDGE 0x15d3
#define PCI_DEVICE_ID_INTEL_ALPINE_RIDGE_C_2C_NHI 0x15d9
#define PCI_DEVICE_ID_INTEL_ALPINE_RIDGE_C_2C_BRIDGE 0x15da
#define PCI_DEVICE_ID_INTEL_ALPINE_RIDGE_LP_USBONLY_NHI 0x15dc
#define PCI_DEVICE_ID_INTEL_ALPINE_RIDGE_USBONLY_NHI 0x15dd
#define PCI_DEVICE_ID_INTEL_ALPINE_RIDGE_C_USBONLY_NHI 0x15de
#define PCI_DEVICE_ID_INTEL_TITAN_RIDGE_2C_BRIDGE 0x15e7
#define PCI_DEVICE_ID_INTEL_TITAN_RIDGE_2C_NHI 0x15e8
#define PCI_DEVICE_ID_INTEL_TITAN_RIDGE_4C_BRIDGE 0x15ea
#define PCI_DEVICE_ID_INTEL_TITAN_RIDGE_4C_NHI 0x15eb
#define PCI_DEVICE_ID_INTEL_TITAN_RIDGE_DD_BRIDGE 0x15ef
#define PCI_DEVICE_ID_INTEL_ICL_NHI1 0x8a0d
#define PCI_DEVICE_ID_INTEL_ICL_NHI0 0x8a17
#endif